iCO Mist Sprinkler Head
Water mist and specialist suppression design for UK projects

Fire Suppression System Design UK

NPHS designs water mist and specialist fire suppression systems for projects across the UK. We review the building, fire strategy, occupancy, water supply, relevant water mist standards, test evidence and installation constraints before developing a system that can be coordinated, installed, commissioned and maintained properly.

Send us your drawings, fire strategy, specification or project details and our design team can review the suppression route before key construction decisions are fixed.

NPHS Provides: Design Install Commission Maintain
Design before installation

Professional fire suppression system design for UK projects

Fire suppression design turns the fire strategy and building information into a coordinated water mist or specialist suppression system that can be installed, commissioned and maintained properly.

The design then establishes what the system needs to achieve, which technology is suitable, what standards and test evidence apply, and how water, plant and installation requirements will be coordinated.

NPHS supports contractors, developers, architects, consultants, housing providers, facilities teams and property owners during the design and specification stage.

We can become involved while the suppression route is still being assessed, after a fire strategy has identified a requirement, or once a project team needs a detailed design that can move into installation.

Early involvement is especially useful where water supply, plant space, ceiling voids, heritage finishes, complex room layouts, retrofit constraints or other building services may affect the final system.

See how NPHS takes a design into installation →
Water mist fire suppression system design
Design-stage support

Who is fire suppression design support for?

NPHS works with the people responsible for turning fire strategy requirements into a coordinated, installable and maintainable suppression system.

01

Main contractors and project managers

Design review, programme input and coordination before ceilings, risers, plant areas and service routes are fixed.
02

Architects and fire consultants

Standards-aware design input, system selection support and evidence review around the building and fire strategy.
03

M&E consultants and contractors

Coordination of water supplies, compact pumps and plant, power, controls, alarms, pipe routes and service interfaces.
04

Developers and housing providers

Design support for flats, apartments, care, supported living, sheltered housing and wider residential schemes.
05

Property owners and facilities teams

Design for refurbishments, alterations, retrofit projects and replacement or extension of existing fire suppression systems.
Send the information you already have. Early architectural drawings, a fire strategy or consultant comments can be enough for NPHS to identify the likely suppression route and the design information still required.
OU
Ozziey Ulker - NPHS Director
Design insight
“The right water mist system starts with the building, not the product. We look at the layout, occupancy, fire strategy, water supply and approval route before deciding what the system needs to achieve.”
Ozziey Ulker Operations Director, NPHS
Design process

What does fire suppression system design include?

Fire suppression design connects the building, fire strategy and selected water mist or specialist system into coordinated information that the site team can actually build from.

The design also needs to cover water supply, system evidence, installation details, commissioning, handover and future maintenance.

The exact design scope depends on the building, selected system, project stage and agreed responsibilities.

  1. Review the building type, use, occupancy, layout and fire strategy
  2. Establish what the suppression system is required to achieve
  3. Identify the relevant water mist standard, test protocol and project approval route
  4. Check whether the proposed system is tested for the application and configuration
  5. Assess water pressure, flow, demand and any storage or pump requirements
  6. Develop water mist nozzle or specialist discharge-point positions within permitted design limits
  7. Plan pipework routes, valves, plant, controls and system interfaces
  8. Coordinate ceilings, lighting, walls, services, structure and access requirements
  9. Prepare the design information required for installation and project review
  10. Carry the agreed design into commissioning, handover and future maintenance
A technically sound design also needs to be buildable. Good project coordination reduces late changes, avoids clashes and gives installers the space and information needed to deliver the system correctly.
System selection

How does NPHS choose the right fire suppression system?

NPHS selects the water mist or specialist suppression route around the building, fire risk, fire strategy, water supply, available space, tested application, relevant standard, project constraints and long-term maintenance requirements.

Domestic and residential water mist

Compact water mist systems can deliver high-performance suppression with dramatically reduced water usage, smaller pipework and discreet ceiling nozzles. They are particularly well suited to homes, apartments, care, supported living, retrofit projects and high-finish interiors.

Commercial and industrial water mist

High-pressure and low-pressure water mist can protect commercial buildings, heritage properties, infrastructure, machinery and selected industrial risks. Reduced water demand and compact plant can make the system easier to accommodate while maintaining high-performance fire suppression.

Specialist suppression

Cease Fire, gaseous suppression and other specialist systems can protect commercial kitchens, electrical equipment, server environments, machinery and defined local risks. The design is built around the ignition source, protected asset, controls, interfaces and maintenance requirements.
Water mist design

What does water mist system design need to consider?

Water mist delivers high-performance fire suppression with dramatically reduced water demand, compact plant, smaller pipework and discreet nozzles.

Those advantages can reduce space requirements and secondary water damage while giving designers far more flexibility in homes, apartments, commercial buildings, retrofit projects and high-finish interiors.

Water mist uses purpose-designed nozzles to create fine droplets that absorb heat quickly, support evaporation and move around the fire plume. The high surface area helps suppress fire rapidly while keeping water flow and discharge volumes dramatically lower.

The design team checks the application against current test evidence and the manufacturer design manual. If a proposed layout moves outside the tested parameters, the performance basis needs technical review before the design proceeds.

For domestic and residential projects, the iCO pump unit measures just 342 mm × 342 mm × 495 mm, helping designers accommodate fire suppression where plant space is limited.

Nozzle positions, ceiling finishes, room layouts and equipment locations should be considered while architectural decisions can still be changed.

Learn more about water mist fire suppression →
Water mist nozzle spacing on flat ceilings
Water mist design checks

Water supply, nozzles, pipework and plant all affect the design

Water mist design needs to treat the system as a complete package. Pump, controls, distribution, sectioning, pipework and discharge points work together, so equipment cannot be selected in isolation.

  1. Water supply: Confirm available pressure, flow and competing demand early rather than assuming the incoming mains can support the system.
  2. Nozzle positions: Keep spacing, wall distances, ceiling heights and orientations within the tested design limits for the selected system.
  3. Obstructions: Coordinate pendant lights, beams, bulkheads and other objects so the tested spray pattern remains clear.
  4. Ceiling voids: Allow enough depth and access for the nozzle, pipework, fixing, adjustment and future inspection.
  5. Pipework: Plan routes from the pump to each nozzle and keep pipe type, length and configuration within manufacturer requirements.
  6. Plant location: Allow suitable space, power, service access and connection to wider controls or alarm interfaces where required.
  7. Finished appearance: Coordinate visible components early where architectural finishes and interior appearance matter.
  8. Maintenance: Make sure valves, equipment and service points remain accessible after construction is complete.
Manufacturer-specific figures such as maximum nozzle coverage, spacing, pipe length and minimum clearances must be checked against the current design manual and project conditions before final issue.
Water mist pipework configurations
Water mist system selection

High-pressure and low-pressure water mist design

NPHS designs high-pressure and low-pressure water mist systems around the building, fire risk, tested application, available water and project requirements.

Both routes can deliver high-performance suppression with dramatically reduced water demand and compact system infrastructure.

High-pressure systems such as iCO and Ultra Fog can provide very fine droplets, compact pipework and rapid heat absorption across domestic, residential, commercial, infrastructure and selected industrial applications.

Low-pressure water mist can provide an effective route for suitable commercial and specialist projects where the tested application and system design support it.

NPHS reviews the project requirements, test evidence, water supply, available space and long-term maintenance needs before selecting and designing the most suitable water mist platform.

Water mist system installation by NPHS →
Project coordination

How does fire suppression design coordinate with the rest of the building?

Suppression systems share ceilings, voids, risers, plant areas and service zones with other trades. Design coordination should happen while those areas can still be changed without major rework.

01

Ceilings and lighting

Water mist nozzles and specialist discharge points need suitable positions, clear discharge patterns and enough space for installation around lighting, bulkheads and ceiling details.
02

Pipe routes and other services

Routes need to work around ducts, cable containment, plumbing, structure and other services while staying within the system design limits.
03

Pumps and plant space

Compact water mist equipment still needs suitable connections, ventilation and service access for commissioning, inspection and future servicing.
04

Controls and alarms

Pumps, valves, control panels, alarm contacts and system interfaces need to be coordinated with the wider fire and building services design.
05

Architectural finishes

Heritage buildings and high-finish interiors can require careful equipment positioning so the system remains technically correct without unnecessary visual impact.
Late design changes can affect tested spacing, pipe lengths, access or water demand. Keeping NPHS involved through coordination helps changes get checked before they reach site.
Standards, testing & evidence

Which standards apply to water mist system design?

Water mist design needs the right standard, test evidence and manufacturer design limits to support the exact system being proposed for the building.

The building, occupancy, fire strategy and project approval route then shape how that evidence is applied.

BS EN 14972-1:2020+A1:2025 provides the current framework for the design, installation, inspection and maintenance of fixed land-based water mist systems. BS EN 14972-17:2025 provides the residential occupancy fire-test protocol for automatic nozzle water mist systems.

BS 8458:2015 was withdrawn by BSI in July 2025. Existing independently tested and certified products may still use that evidence, but the proposed design should be assessed against the current certification, design limits, fire strategy and project approval route.

Approved Document B and the relevant national or local Building Regulations route may also shape the wider fire safety strategy and project approval discussion.

ReferenceDesign relevance
BS EN 14972-1:2020+A1:2025Current framework for fixed land-based water mist design, installation, inspection and maintenance.
BS EN 14972-17:2025Residential occupancy fire-test protocol for automatic nozzle water mist systems.
BS 8458:2015Previous UK domestic and residential water mist code. Existing certification and test evidence may remain relevant to specific systems.
Manufacturer fire-test evidenceConfirms the applications, configurations and performance limits supported by the tested water mist system.
Manufacturer design manualDefines system-specific nozzle spacing, flow, pressure, pipework, plant and installation limits.
Fire strategy / project approval routeConnects the proposed water mist design to the building-specific fire safety strategy and approval process.
Approved Document B / local regulatory routeBuilding Regulations guidance and the wider project compliance discussion.
Design evidence check:
Building + fire strategy + application + standard + test evidence + design limits

NPHS can support design, specification, installation, commissioning and documentation. Final project acceptance remains with the relevant appointed project and regulatory stakeholders.

Different buildings, different designs

Fire suppression design for domestic, residential, commercial and industrial projects

Building type changes the design problem. Occupancy, fire strategy, water demand, available space, finishes, hazard and maintenance arrangements all influence the final water mist or specialist suppression design.

01

Domestic homes

Individual homes, loft conversions and open-plan layouts can benefit from discreet water mist systems designed around room geometry, escape strategy, Building Control requirements and available space.
02

Residential developments

Flats, apartments, supported living, sheltered housing and care schemes can use compact water mist systems designed around occupancy, repeated layouts, shared services, access and long-term management.
03

Commercial buildings

Offices, hotels, public buildings and mixed-use property can use high-pressure or low-pressure water mist designed around the fire strategy, services, plant space and operational requirements.
04

Industrial and warehouse risks

Machinery, process risks, infrastructure and selected industrial applications can use Ultra Fog or other specialist water mist systems where the tested application supports the risk.
05

Heritage and retrofit projects

Existing structures, restricted voids, protected finishes, limited plant space and difficult routes are strong applications for compact water mist systems and early design coordination.
Project experience

Design needs to work at building scale

NPHS designs water mist and specialist suppression systems for projects ranging from individual homes to major residential, commercial, heritage and industrial schemes.

Scale, occupancy, water supply, selected technology and coordination requirements can vary significantly from one project to the next.

On repeated-layout residential schemes, water mist design needs to work consistently across multiple homes while allowing for site conditions and services. In high-finish properties, discreet nozzles and compact plant can protect the architecture.

In industrial projects, the protected hazard and equipment arrangement can determine whether Ultra Fog or another specialist system is appropriate.

The design stage is where those differences are resolved before they become installation problems.

View commercial NPHS projects →
Blueprints and a hard hat in a fire suppression installation project interior
Early coordination

What problems can late fire suppression design create?

Suppression design becomes harder once ceilings, services, plant areas and architectural details have already been fixed. Early checks give the project team more options and reduce avoidable redesign.

  1. Ceiling voids may be too shallow for the selected nozzle or pipework arrangement
  2. Lighting, bulkheads, beams or other services may obstruct the required discharge pattern
  3. Pipe routes may clash with ducts, containment or structure
  4. Plant rooms or cupboards may not have enough space for the selected equipment
  5. Incoming water pressure or flow may be lower than the assumed design condition
  6. Architectural finishes may make the proposed visible components unacceptable
  7. Room changes may push nozzle spacing, coverage or pipe lengths outside tested limits
  8. Valves, pumps or service points may become difficult to inspect and maintain
For live projects, the useful point to involve NPHS is before these decisions become expensive to change. A drawing review can identify design constraints early enough for the project team to act on them.
Whole-life design

From design through installation, commissioning and maintenance

A suppression design should remain useful after the drawing has been issued.

NPHS can carry the project through installation and commissioning so the installed system can be checked against the agreed design.

Commissioning should cover the water supply, controls, pump operation, water mist nozzles or specialist discharge points, alarms and interfaces where relevant.

Clear handover records then give the client and building team a reference point for future inspection, maintenance, alterations and changes of use.

Fire suppression system maintenance →
Project stage Design value
Installation+

Installers work from coordinated information covering pipe routes, nozzles or specialist discharge points, plant, valves and interfaces.

Commissioning+

Checks confirm that the installed system operates as required and reflects the agreed design.

Handover+

Drawings, system information, commissioning evidence and operating requirements support the building record.

Inspection and servicing+

Accessible equipment, clear records and known design limits make future system checks and defect investigation easier.

Alterations and change control+

Future building changes can be checked against the original design so coverage, access and system performance are not compromised.

Start the design review

What information does NPHS need to design a fire suppression system?

Send whatever information is currently available. Early plans and a fire strategy can be enough to begin reviewing the likely suppression route and identify the information needed for detailed design.

  1. Architectural floor plans and room layouts
  2. Reflected ceiling plans where available
  3. Sections, ceiling heights and known void depths
  4. Fire strategy or fire consultant requirements
  5. Building type, use, occupancy and project stage
  6. Known suppression standard, specification or approval requirements
  7. Water supply pressure and flow information where available
  8. M&E layouts, plant constraints and service coordination information
  9. Building Control, insurer, client or consultant comments
  10. Programme dates, phasing, access or retrofit constraints
Missing information does not always prevent an initial review. NPHS can identify what still needs to be confirmed before the project moves into detailed design or installation.
Why NPHS

Why use NPHS for fire suppression system design?

NPHS is the UK’s leading and largest water mist installer, designing water mist and specialist suppression systems for domestic, residential, commercial and specialist applications across the UK.

Our design capability includes iCO, Ultra Fog, Cease Fire and gaseous suppression systems. That gives project teams access to compact domestic and residential water mist, commercial and industrial mist, and targeted specialist protection from one experienced contractor.

NPHS can carry the project from early drawings and specification through design coordination, installation, commissioning, handover and planned maintenance.

That keeps system evidence, design limits, site delivery and project documentation connected from the first design decision through to long-term support.

Learn about NPHS water mist installation →
Fire suppression system design UK

Send NPHS your project drawings

Send us your drawings, fire strategy, specification or project notes and our team can review the suppression design requirements.

We can assess the building, occupancy, water supply, water mist standards, tested application, plant space, installation constraints and long-term maintenance requirements before advising on the next design stage.

Fire suppression design questions

FAQs

What is included in fire suppression system design?
Fire suppression design can include review of the building and fire strategy, water mist or specialist system selection, standards and test evidence, water supply, nozzle or discharge-point layout, pipe routes, pumps and plant, controls, service coordination, installation information and commissioning requirements. The exact scope depends on the project and selected suppression system.
When should a fire suppression designer become involved in a project?
Early involvement is useful once the building layout and fire strategy are developed enough to identify suppression requirements. Reviewing the system before ceilings, plant areas and service routes are fixed gives the project team more options and can reduce clashes or redesign later.
What information is needed to design a water mist system?
Useful information includes floor plans, room use, ceiling heights, fire strategy requirements, water supply data, reflected ceiling plans, plant locations and known project constraints. The proposed system must also be checked against the test evidence, current certification and manufacturer design limits for the application.
Why is water mist such a strong design option?
Water mist delivers high-performance fire suppression with dramatically reduced water demand, compact plant, smaller pipework and discreet nozzles. Those advantages can make the system easier to accommodate in homes, apartments, commercial buildings, retrofit projects, heritage properties and other space-constrained environments.
Which standards apply to water mist system design?
BS EN 14972 provides the current framework for water mist system design, installation, inspection and maintenance, with BS EN 14972-17 covering the residential occupancy fire-test protocol for automatic nozzle water mist systems. Existing BS 8458 certification and test evidence may also remain relevant to specific systems.
Why does water supply need to be checked during design?
A water mist system still needs the correct pressure and flow to operate as designed. Confirming the available supply early allows NPHS to size the compact pump and system correctly, account for competing demand and determine whether any additional water supply arrangement is required.
Can NPHS design and install the same fire suppression system?
Yes. NPHS designs and installs water mist systems, Cease Fire systems, gaseous suppression and other specialist suppression solutions, then supports commissioning, handover and planned maintenance. Keeping design and delivery connected can make site coordination, change control and final commissioning easier to manage.
Can NPHS review a fire suppression design that is already partly developed?
Yes. Send the available drawings, specification, fire strategy and known system information. NPHS can review the proposed route, identify missing design information and flag constraints that need to be resolved before detailed design, installation or commissioning.