Ultra Fog Commercial Water Mist Systems

NPHS supplies, designs, installs, commissions and maintains Ultra Fog high-pressure water mist systems for suitable commercial, industrial and specialist applications across the UK.

Ultra Fog technology combines fine water droplets, compact pipework and application-specific system design to provide effective fire suppression while controlling water demand and reducing the space required for some conventional sprinkler arrangements.

NPHS Can Help With: System Selection Design & Installation Commissioning Maintenance
Commercial high-pressure water mist

Why choose an Ultra Fog water mist system?

Ultra Fog specialises in high-pressure water mist technology for land, marine, offshore and transport applications. NPHS uses the technology for suitable commercial and specialist fire suppression projects in the UK.

The existing NPHS commercial page highlights the practical reasons project teams consider water mist: reduced water demand, smaller distribution pipework, compact equipment and the ability to protect buildings where water damage and space are important considerations. Ultra Fog high-pressure pumps force water through purpose-designed stainless-steel nozzles, creating large numbers of fine droplets. The complete system can include pumps, nozzles, valves, electrical controls, accumulators and other components selected around the protected application. NPHS can review the project before the technology has been selected, or take forward an Ultra Fog solution already specified by a consultant or fire strategy. Explore commercial water mist and fire suppression →
Ultra Fog high-pressure water mist nozzle and Ultra Fog fire extinguishing system branding
Comparison of traditional sprinkler water discharge and Ultra Fog water mist
How it works

The science behind Ultra Fog water mist fire suppression

Water mist suppresses fire primarily through rapid heat absorption, local interaction with oxygen around the fire and reduction of radiant heat transfer.

Ultra Fog states that its systems typically produce droplets in the region of 30 to 200 microns. The large combined surface area of those droplets allows them to absorb heat efficiently. As water evaporates, it expands into steam and can reduce the oxygen concentration locally around the flame. The suspended mist can also reduce radiant heat transfer to nearby combustible materials. Compared with conventional sprinkler arrangements, suitable high-pressure water mist systems can achieve the required suppression objective using considerably less water. The exact performance depends on the proprietary system, fire-test evidence, nozzle arrangement, operating pressure, protected hazard and hydraulic design. View Ultra Fog water mist technology →
Commercial, industrial and specialist applications

Where can Ultra Fog water mist be used?

Ultra Fog technology has been developed across a wide range of land, marine, offshore and transport applications. For UK building projects, suitability depends on the specific hazard and available system evidence.

Commercial buildings

Suitable applications can include offices, hotels, hospitality venues, public buildings, healthcare facilities and other commercial premises where water demand and plant space matter. Commercial suppression systems →

Heritage & sensitive buildings

Water mist can be attractive where limiting water discharge and protecting significant interiors or assets is an important project objective.

Industrial & specialist risks

Ultra Fog also develops systems for machinery spaces, offshore environments, transport applications and other defined hazards supported by appropriate testing. Industrial fire suppression systems →
Ultra Fog applications across marine, land, offshore and rolling stock fire suppression
PM
NPHS engineer inspecting a fire suppression nozzle
Commercial fire suppression expertise
“Our initial check looks at building use, fire strategy, water supply, available space and the relevant standard.”
Paul McFarling Managing Director, NPHS
Lower water demand and compact distribution

A space-conscious commercial fire suppression option

One of the strongest messages from the existing NPHS commercial page is the practical value of reduced water demand. Ultra Fog publishes substantially lower water consumption figures for suitable high-pressure applications compared with many conventional sprinkler and low-pressure mist arrangements. That can reduce the associated water storage requirement and allow smaller distribution pipework in some projects. These characteristics can be useful where plant space, riser sizes, structural constraints or retrofit routes make conventional arrangements difficult. Actual water demand, tank capacity and pipe sizes should always be established from the tested system and hydraulic design rather than assumed from technology type alone. Compare water mist and traditional sprinklers →
Ultra Fog open water mist nozzles used in commercial fire suppression systems
Long-term inspection and servicing

Ultra Fog nozzle testing and maintenance

A commercial water mist system needs planned inspection and maintenance throughout its service life.

The original NPHS page highlights Ultra Fog’s nozzle test tool as an important maintenance feature. Ultra Fog developed the tool so that applicable nozzles can be function-tested and flushed without removing the nozzle or breaking the temperature-sensitive glass bulb. That allows maintainers to check nozzle operation, flush pipe ends and identify issues that could affect future system performance. NPHS can provide planned inspection and maintenance for suitable commercial water mist systems, including systems installed by another contractor where the necessary system information is available. Fire suppression system maintenance →
Standards, testing and project evidence

What standards apply to commercial water mist systems?

BS 8489-1:2016 remains a current British Standard providing recommendations for the design and installation of industrial and commercial water mist systems. The wider standards position is application-specific. BS EN 14972-1:2020+A1:2025 also provides the current general European framework for fixed land-based water mist systems, supported by application-specific fire-test protocols within the EN 14972 series. The relevant route therefore depends on the protected hazard, system certification, accepted fire-test evidence and project requirements. NPHS can help review the applicable system evidence during specification and design.
ReferenceProject relevance
BS 8489-1:2016Current UK code of practice covering industrial and commercial water mist design and installation.
BS EN 14972-1:2020+A1:2025General framework for fixed land-based water mist systems.
Application fire-test evidenceDemonstrates performance for the specific hazard or occupancy being protected.
Ultra Fog design documentationDefines proprietary system limits, nozzles, pressures, hydraulic requirements and components.
System selection should follow:
Hazard + fire testing + hydraulic design + project requirements
From specification to long-term support

How NPHS supports Ultra Fog projects

NPHS can enter the project at early specification stage, work from an existing design or provide installation, commissioning and later maintenance support.
01

Project review

Review the building, hazard, fire strategy, water supply, plant space and relevant system evidence.
02

System design

Coordinate pumps, nozzles, pipework, hydraulic calculations and relevant fire alarm or control interfaces.
03

Installation

Install the agreed Ultra Fog system and coordinate works with the wider construction or refurbishment programme.
04

Commissioning

Check the completed system against the agreed design and provide appropriate handover documentation.
05

Maintenance

Provide planned inspection, testing, servicing and remedial support throughout the system life.
Water Mist – Commercial | Ultra Fog

Planning a commercial water mist project?

Send NPHS your drawings, fire strategy, hazard information or current specification. We can review whether Ultra Fog high-pressure water mist is suitable for the application and advise on design, installation, commissioning and maintenance requirements.
Commercial water mist

Ultra Fog water mist FAQs

What is an Ultra Fog water mist system?

Ultra Fog is a proprietary high-pressure water mist fire suppression system. High-pressure pumps deliver water through specialist nozzles that generate fine droplets designed to absorb heat efficiently and suppress fire using controlled volumes of water.

Where can Ultra Fog systems be used?

Ultra Fog develops systems for land, marine, offshore and transport applications. In UK commercial projects, suitability depends on the building or hazard, relevant fire-test evidence, system certification, design requirements and project fire strategy.

Does commercial water mist use less water than sprinklers?

Suitable high-pressure water mist systems can use substantially less water than many conventional sprinkler arrangements. Exact demand depends on the protected hazard, nozzle characteristics, system design and fire-test parameters.

What standard applies to commercial water mist?

BS 8489-1:2016 remains a current UK code of practice for industrial and commercial water mist system design and installation. BS EN 14972-1:2020+A1:2025 also provides a general framework for fixed water mist systems, supported by application-specific testing within the EN 14972 series.

Can NPHS maintain an existing Ultra Fog system?

NPHS can inspect and maintain suitable commercial water mist systems, including existing installations where the necessary system documentation, components and maintenance requirements can be established.